4.9 Change User Code (Master User Only)
Press `25
The panel requests a user number.
Enter the user to be edited.
Example shows User 2.
If you wish to change the user
code, enter the new code twice. If
you wish to edit the user
attributes only, enter the current
code twice.*
The system shows attribute option 1.
Use the [ and ] keys to
select the option you wish to edit,
or select it directly using the
numeric keys
Example shows option 3.
Toggle the option on or off using
the - key. If the option is on,
the k icon is visible. If the option
is off, the k icon is not visible.
Example shows option 3 off.
Repeat for all options as required
Press ` to save the changes
NOTE: To delete an existing user code and return to the user menu, press [ after entering the
user number.
*NOTE: For four- and five-digit user codes, you must press ` after entering the code to proceed.
For a six-digit code, the code is accepted automatically.
?
option: User Code Attributes OFF ON
1 Omit (Bypass) Zones Disable [Enable]
2 Duress Code Only [Disable] Enable
3 Duress Enabled [Off] On
[default]
4.10 Activating PGM from the Keypad (Master User Only)
Press `27
Any PGM output programmed as “RKP
Controlled” will switch on for 15
seconds. Which PGM output is
controlled by the keypad is
determined by your engineer.

Other manuals for Pyronix Matrix 6/816

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 6/816 and is the answer not in the manual?

Pyronix Matrix 6/816 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 6/816
CategoryControl Panel
LanguageEnglish

Related product manuals