6.7 Recalling the event log
The event log can now be displayed at any time, when the Paragon E is unset. The
event log is displayed by pressing.
The day led will flash and event information from the latest alarm activation is displayed
pressing any key will then show the previous event information. When all the four
have been displayed the day Led will stop flashing and another function can be
selected.
6.8 Omitting one or more zones
If one or more immediate zones are triggered whilst in exit mode a low pitched error
tone will be produced. If any zones remain triggered at the end of the exit timer, the
error tone will continue. Key in the User code. The display will show the zones which
remain triggered. Make a note of any triggered zones. Key in the user code which will
clear the display.
Check for any obvious reason for these zones to have been activated. This may
simply be due to a monitored door or window being left open or a pet being left in a
protected area. If the fault cannot be rectified it is possible to omit faulty zones, but this
should only be used as a last resort if the building is to be left unoccupied.
Example
Set panel (error tone will be heard).
Wait for the end of the exit timer.
Error tone is still being produced.
Key in the user code.
Triggered zones will be displayed.
Note triggered zones.
Key in user code to clear display and error tone then investigate fault(s) if
possible.
Set panel again.
then: Check the display If the zones are not being triggered exit via normal
route.
or: If displays shows zones are as still being triggered
then enter:
now enter: the number of the zone to be omitted (1 to 4)
then: - Entry / Exit timer will start again.
then: exit building by normal route.
6.9 The user if allowed by the engineer can clear the log. This is achieved by
pressing:
6.10 Clearing the display after an activation
After an alarm condition enter the User code :
This unsets the panel.The LEDs will display any activated zones.
Enter User code again. This clears the display.
9
RINS 011 ISSUE-1
6 USER FACILITIES
SHIFT PA (PERSONAL ATTACK)
EASY-SET UP ARROW
FIRE DOWN ARROW
6.1 Full Setting the panel
Enter either of the following:
User Code
By using this method, maximum volume of the entry / exit tone will be heard.
or
By using this method, no sounds will be emitted except for an acknowledge
tone at the beginning and the end of the entry / exit time.
6.2 Part setting the panel
Part set 1 (eg downstairs only armed):
or both will give a silent setting
Part set 2 (eg upstairs only armed):
Enter or both will give a silent setting
6.3 Unsetting the panel
The panel can be unset by entering the building via the entry / exit route and then
keying the user code.
6.4 Activating the Personal Attack Alarm (PA).
To activate the personal attack alarm enter
6.5 Activating the Fire Alarm.
To activate the Fire Alarm enter
6.6 Turning Chime On and Off (Panel must be in day mode)
Enter
When the chime mode is selected a three note chime will be produced by the internal
sounder and any extension speakers when an Entry / Exit zone is activated. The same
key sequence can be used to turn off the chime facility.

Other manuals for Pyronix Paragon E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Paragon E and is the answer not in the manual?

Pyronix Paragon E Specifications

General IconGeneral
BrandPyronix
ModelParagon E
CategorySecurity System
LanguageEnglish

Related product manuals