EasyManuals Logo
Home>Quectel>Control Unit>EC2 Series

Quectel EC2 Series Command Manual

Quectel EC2 Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
LTE Module Series
EC2x&EG9x&EM05 SMTP AT Commands Manual
EC2x&EG9x&EM05_SMTP_AT_Commands_Manual 7 / 31
Step 5: Clear the email content.
AT+QSMTPCLR will clear the email content configured in Step 3. The attached files should be
deleted by AT+QFDEL. For more details of these commands, please refer to
Quectel_EC2x&EG9x&EM05_FILE_AT_Commands_Manual. Then repeat Step 3 and 4. If the
SMTP server information and user information need to be changed, then Step 2 to Step 4 should
be repeated.
If emails have not been sent for a long time, such as 30 minutes or even longer, then the PDP
context should be deactivated by AT+QIDEACT=<contextID>. For more details, please refer to
Quectel_EC2x&EG9x&EM05_TCP(IP)_AT_Commands_Manual.
1.3. Description of Data Mode
The COM port of EC2x&EG9x&EM05 modules has two working modes: AT command mode and data
mode. In AT command mode, the inputted data via COM port will be treated as AT command, while in data
mode, it will be treated as data.
Inputting “+++” or pulling up DTR (AT&D1 should be set first) can make the module exit from data mode.
To prevent the “+++” from being misinterpreted as data, the following sequence should be followed:
1) Do not input any character within 1s or longer before inputting “+++”.
2) Input “+++” within 1s, and no other characters can be inputted during the time.
3) Do not input any character within 1s after “+++ has been inputted.
When AT+QSMTPBODY is executed, the COM port will enter into data mode. All inputted data will be the
body of email. If the inputted data reaches the <body_length> or the time reaches <input_time>, the port
will exit from data mode automatically. If the inputted data is less than the <body_length>, customers can
finish editing body by inputting “+++” or changing DTR level from low to high before <input_time> reaches.
In such case, the COM port cannot reenter data mode by executing ATO command.

Other manuals for Quectel EC2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel EC2 Series and is the answer not in the manual?

Quectel EC2 Series Specifications

General IconGeneral
BrandQuectel
ModelEC2 Series
CategoryControl Unit
LanguageEnglish

Related product manuals