LTE Standard Module Series
EC200U_Series_Hardware_Design 81 / 94
Table 51: EC200U-AU Conducted RF Receiving Sensitivity
5.7. ESD
If the static electricity generated by various ways discharges to the module, the module maybe damaged
to a certain extent. Thus, please take proper ESD countermeasures and handling methods. For example,
wearing anti-static gloves during the development, production, assembly and testing of the module;
adding ESD protective components to the ESD sensitive interfaces and points in the product design.
The following table shows the module electrostatics discharge characteristics.