1-866-933-7486
4
www.QuestOnTheJob.com
sales@QuestOnTheJob.com
quest
quest
Quest PowerDry 1300 Installation, Operation and Maintenance Instructions
1. Safety Certications
The Quest PowerDry 1300 conforms to standards ANSI/UL 474 and CSA C22.2 No.92.
2. Specications
Part No. 4032360
Power 5.0 amps, 110-120 VAC, Grounded
Water 8 gallons/day @ AHAM (80°F, 60%)
Removal 16 gallons/day maximum @ staturation
Blower 190 CFM without external ducting
Refrigerant 1 lb, 2 oz. R410A
Charge
Operating 33°F to 100°F
Range
Filters: 12” x 12” x 1” Pleated Media MERV-8
Duct Outlet - 10” Lay-Flat
Options
Warranty Five years;
1st year 100% of Parts and Labor
2nd-5th year 100% of Parts of sealed
refrigeration system.
Dimensions Width 20”, Depth 17”, Height 30”
Weight 82 lbs.
3. Handle Installation
IMPORTANT: Handle installation REQUIRED prior to rst use.
1. Remove handle from shipping position
2. Locate 4 1/4-20 x 1/2” hex bolts inside manual or packed parts bag
3. Assemble handle to top two threaded inserts on each side of the rear housing
4. Tighten the bolts using 3/8” hex driver or wrench
4. Operation
Place dehumidier inside structure, place condensate hose into a drain, or a very large container, and turn
on. To decrease drying times, make sure all windows and doors are closed to the outside and seal off the wet
area from any unaffected areas.