RADWIN2000+SeriesUserManual Release4.2.40 6‐29
TelnetAccesstoEitherODU
displayPM<interface:AIR,LAN1>
<interval:current,day,month>
Showstheperformancemonitortablesforeach
inte rfaceaccordingtouserdefinedmonitoring
intervals
displaybands Displaysavailablebands
displayldpc_mode Onoroff;defaultoff
Table6‐3:ODUTelnet‐SetImmediateCommands
Command Explanation
setip<ipaddr><subnetMask>
<gateway>
SettheradiounitIPaddress,subnetmaskand
gateway.Theusermustresettheradiounitafterthe
commandcompletion
settrap<index:1‐10><ipaddr>
<port:0‐65535>
Setaspecifictrapfromthetrapstable(e.g.settrap3
192.168.101162)
setreadpw<oldpasswd><passwd> Setthereadaccesspassword(ReadCommunity)
setwritepw<oldpasswd><passwd>
Settheread‐writeaccesspassword(R ead‐Write
Community)
settrappw<oldpasswd><passwd> SetthetrapCommunitystring
setbuzzer<mode> mode:0=off,1=auto,2=on
settpc<power:Valuebetween
minimalTxpower,andmaximalTx
power>
SettheradiounitTxPower.Ifawrongvalueis
entered,bothminandmaxvaluesshallbedisplayed
intheerrorreply
setname<newname> Setthenameofthelink
setlocation <newlocation> Setthenameofthelocation
setcontact<newcontact> Setthenameofthesitemanager
setethernet<port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>
SetthemodeandspeedoftheEthernetport
reboot
Resetstheradiounit.Theuseriswarnedthatthe
commandwillresettheradiounit.AnewTelnet
sessiontotheradiounitmaybeopenedafterthe
resetiscomplete.
help Displaystheavailablecommands
Table6‐2:ODUTelnet‐DisplayCommands(Continued)
Command Explanation