Re S.p.A. T-two – standard model
Rev. 05/15 12/14
Function 38 – Remote SETPOINT acquisition
You can use this function to enable or disable remote acquisition of the setpoint.
Press to access the function, the display indicates the current state of this function.
Press + / – to select OFF if you wish to set-up the setpoint using function F.18, or On if you wish to
activate remote acquisition of the setpoint.
Press to confirm.
Function 39 – Remote SETPOINT filter
When the setpoint value is acquired remotely (F.38 = On), you can use this function to set-up a suitable
value for the dedicated digital filter, in order to obtain a stable signal that is free from unwanted
variations. The higher the filter setting, the more the signal is filtered.
Press to access the function, the display indicates the corresponding value.
Press + / – to set-up the desired filter value.
Press to confirm.
Function 40 – Remote acquisition of the DANCER ROLL AIR PRESSURE
You can use this function to enable or disable remote acquisition of the dancer roll air pressure value.
Press to access the function, the display indicates the current state of this function.
Press + / – to select OFF if you wish to set-up the pressure using function F.32, or On if you wish to
activate remote acquisition of the pressure value.
Press to confirm.
Function 41 – Remote DANCER ROLL AIR PRESSURE filter
When the dancer roll air pressure value is acquired remotely (F.40 = On), you can use this function to
set-up a suitable value for the dedicated digital filter, in order to obtain a stable signal that is free from
unwanted variations. The higher the filter setting, the more the signal is filtered.
Press to access the function, the display indicates the corresponding value.
Press + / – to set-up the desired filter value.
Press to confirm.
Function 48 – Retain in STOP mode the last torque value used in AUTO mode
Normally, when the machine is stationary, the torque percentage set-up in F.1, with the contribution of
the parameters set-up in F.16 and F.17, is applied to the reel; however, this means that torque applied
when the machine is restarted is always the same and this can result in a marked deterioration in the
regulation during restarts as the diameter decreases. To overcome this problem you can enable this
function that can be used to retain the last torque value used in AUTO (which will continue to decrease
as the diameter diminishes) as the machine restart torque value.
Press to access the function, the display indicates the current state of this function.
Press + / – to select OFF if you wish to use the parameter set-up in F.1 as the starting torque, or On if
you wish to retain the last value used in AUTO mode as the starting torque.
Press to confirm.
Function 97 – Entering the “Admin”password
In order to prevent the user from modifying the regulator settings and/or parameters, access to the
functions included in the T-two “regulator set-up and parameters menu” is restricted to the personnel
authorised when setting the unit up. Therefore, it is necessary to enter the pre-defined “Admin”
password in order to access these functions (using F.98).
Press to access the function, the display indicates the corresponding value.