Re S.p.A. T-two – standard model
Rev. 05/15 5/14
Setting up the regulator
The following is a brief summary of the functions that are available for setting up the tension regulator.
For a complete description, consult Detailed description of the regulator set-up and parameters menu
(P.1) on page 7.
To access the set-up environment press and hold the for approximately 3 seconds. The letter P.
Appears on the display, followed by the menu identification number. Press the + / – keys to scroll to
the regulator set-up and parameters menu “P.1”. Press and hold the key again to access the menu.
The display indicates the letter F. followed by the number that identifies the first available function.
Use the + / – keys to scroll through the list of programming functions.
To modify the parameters associated with each individual function, select the desired function, then
press the key: The display indicates the current parameter value. Use the + / – to set the desired
value, then press the key to confirm.
To save the new settings, select the first function in the menu and press the – key, or select the last
function and press the + key, after approx. 3 seconds the unit will exit the menu and the data will be
saved.
Regulator set-up and parameters menu (P.1)
“Proportional” regulator in AUTO state
“Integral” regulator in AUTO state
“Derivative” regulator in AUTO state
“Proportional” regulator in ACC state
“Integral” regulator in ACC state
“Derivative” regulator in ACC state
“Proportional” regulator in DEC state
“Integral” regulator in DEC state
“Derivative” regulator in DEC state
“Proportional” regulator in STOP state
“Derivative” regulator in STOP state
Setpoint (Tension/Position)
Torque in EMERGENCY state (%)
Dancer roll air pressure (%)
Tension/position alarm modes