99 AC output Voltage
Users can select to have the PCL inverter-charger sound an alarm at a programmable battery
voltage. This will need to be a higher value than Program 29 Low DC Cut-off Voltage as it will
warn users that the battery is discharging before ultimately disconnecting.
Allows users to customize AC output voltages for devices that might need to meet a very
specific AC powering criteria.
98 Low Battery Voltage Alarm
98
99 AC output voltage
Low voltage battery alarm
The default is 10.5V. The setting range is 10.5V-12.5V
with increments of 0.1V. This setting will be at least
0.5V greater than setting #29
V
BATT
The default is 120V, can be set between 100V-120V
with increments of 5V
V
OUTPUT