25
Combination Gas Control, Status Light Troubleshooting
STATUS LIGHT
CODE
CONDITION POTENTIAL SOLUTION(S)
OFF
Combination gas control turned off Follow the operating instructions in the Use & Care
Manual to turn on the combination gas control
Pilot not lit Follow the lighting instructions as detailed on this water
heater and it's Use & Care manual to light the pilot
Insufcient power supply (millivoltage) Check thermopile connector to the combination gas
control to ensure it is properly connected
Check thermopile wires for damage and replace if
needed
Inspect pilot assembly
Constantly lit
Pilot recently extinguished and
Thermopile is cooling down
Temperature knob recently turned to
OFF position
Follow the lighting instructions as detailed on the water
heater and it's Use & Care manual to light the pilot
One (1) blink every three
(3) seconds
Normal Operation
Temperature knob in pilot position and
pilot is lit
Set temperature knob on combination gas control to
desire setting
Two (2) blinks every three
(3) seconds
Low thermopile voltage however pilot
is lit
Check thermopile connector to the combination gas
control to enssure it is properly connected
Check thermopile wires for damage and replace it
needed
Inspect pilot assembly
Four (4) blinks every
three (3) seconds
High water temperature limit tripped Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Five (5) blinks every three
(3) seconds
Water temperature sensor failure Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Seven (7) blinks every
three (3) seconds
Combination gas control failure Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
Eight (8) blinks every
three (3) seconds
False pilot ame signal Contact a qualied service technician.
See "IF YOU NEED SERVICE" on page 28
STATUS LIGHT CODE
FLASHES STATUS
2
4
5
7
8
1
0
Thermopile Voltage Low
High Temperature Shutdown
Temperature Sensor Failure
Gas Control or Valve Failure
Flame Sense Error
Normal Operation
Control O/Pilot Out
If Pilot is lit, Status Light will briey stay lit when Knob is turned to OFF.
If the Status Light is not blinking, relight the
Pilot. To light Pilot, see Lighting Instructions
on water heater. If Status Light blinks more
than one ash every three seconds, see
Installation Instructions.
Example: 3 sec. pause