43
TM061 Rheem 27 Water Star Service Instructions – Issued: 11/10
REV A Issued 08/13
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
Error Code 82
Gas Type Control Data Failure.
Error Code 82
Is the correct gas type
connector fitted to suit the
model and gas type?
NO
Isolate power and remove
power cord from GPO for 10
seconds. Restore power.
Install the correct gas type
connector to suit the model
and gas type of appliance.
YES
Is a gas type connector
inserted in terminal R on
control PCB?
Install a gas type connector to
suit the model and gas type of
appliance.
NO
YES
Has error code 82
reappeared after
restoring power supply?
Replace control PCB and gas
type connector.
The appliance seems to be
normal.
YES
NO