6
General Information
Minimum
Model
Number
Voltage
Phase
Freq
Rated Load
Amperes
(RLA)
Locked Rotor
Amperes
(LRA)
Fan
Motor
Full
Load
Amperes
(FLA)
Minimum
Circuit
Ampacity
Amperes
Maximum
Amperes Amperes
Face
Area
Sq. Ft .
[m
2
]
No.
Rows
CFM
[L/s]
Refrig .
Per
Circuit
(oz.)
[g]
Net
Lbs.
[kg]
Shipping
Lbs. [kg]
Fuse or HACR
Circuit Breaker
Outdoor Coil We ightCompressor
ELECTRICAL PHYSICAL
(-)A1618AJ1NA
(-)A1624AJ1NA
(-)A1630AJ1NA
(-)A1636AJ1NA
(-)A1642AJ1NA
(-)A1648AJ1NA
(-)A1660AJ1NA
(-)A1660BJ1NA
(-)A1636AC1NB
(-)A1642AC1NB
(-)A1648AC1NB
(-)A1660AC1NB
208-230
208-230
208-230
208-230
208-230
208-230
208-230
208-230
208-230
208-230
208-230
208-230
1
1
1
1
1
1
1
1
3
3
3
3
60
60
60
60
60
60
60
60
60
60
60
60
9.0/9.0
10.3/10.3
12.8/12.8
15.4/15.4
16.7/16.7
17.0/17.0
23.7/23.7
23.7/23.7
10.4/10.4
11.2/11.2
13.6/13.6
15.9/15.9
47.5
61.6
67.3
83.9
109.0
123.9
152.5
152.5
73
88
83.1
110
12/12
14/14
18/18
23/23
25/25
25/25
34/34
34/34
17/17
18/18
21/21
24/24
15/15
20/20
25/25
30/30
30/30
30/30
40/40
40/40
20/20
25/25
25/25
30/30
12.15 [1.13]
14.82 [1.38]
16.15 [1.50]
18.85 [1.75]
24.23 [2.25]
28.27 [2.63]
32.31 [3.00]
60.58 [5.63]
18.85 [1.75]
24.23 [2.25]
28.27 [2.63]
32.31 [3.00]
1
1
1
1
1
1
1
2
1
1
1
1
2404 [1134]
2851 [1345]
3914 [1847]
4340 [2048]
4450 [2100]
4658 [2198]
4776 [2254]
5124 [2418]
4340 [2048]
4450 [2100]
4658 [2198]
4776 [2254]
82 [2325]
87 [2466]
113 [3203]
108 [108]
150 [4252]
174 [4933]
201 [5698]
308 [8732]
108 [3062]
150 [4252]
174 [4933]
201 [5898]
148 [67.1]
163 [73.9]
188 [85.3]
200 [90.7]
246 [111.6]
261 [118.4]
289 [131.1]
300 [136]
200 [90.7]
246 [111.6]
261 [118.4]
289 [131.1]
155 [70.3]
170 [77.1]
195 [88.4]
207 [93.9]
253 [114.8]
268 [121.6]
296 [134.3]
307 [139.2]
207 [93.9]
253 [114.8]
268 [121.6]
296 [134.3]
0.70
0.60
1.40
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
3.50
20/20
20/20
30/30
35/35
40/40
40/40
50/50
50/50
25/25
25/25
30/30
35/35
(-)A16
GENERAL INFORMATION
Electrical and Physical Data - cont�
UNIT MODEL NUMBER EXPLANATION
AJ1NA
(-)
A
TYPE
N - NON-COMM
TYPE
1 - SINGLE STAGE
VOLTAGE
J= 1 PH, 208-230/60
C= 3 PH, 208-230/60
D= 3 PH, 460/60
Y= 3 PH, 575/60
CAPACITY
18 = 18,000 BTU/HR [5.28 kW]
24 = 24,000 BTU/HR [7.03 kW]
30 = 30,000 BTU/HR [8.79 kW]
36 = 36,000 BTU/HR [10.55 kW]
42 = 42,000 BTU/HR [12.31 kW]
48 = 48,000 BTU/HR [14.07 kW]
60 = 60,000 BTU/HR [17.58 kW]
SEER
CONDENSER
BRAND
13
24
MAJOR SERIES
MINOR SERIES
DIMENSIONAL DATA
(-)A13
18, 36 24, 30 42 48 60
27 [686] 25 [635] 31 [787] 27 [686] 31 [787]
29.75 [756] 29.75 [756] 29.75 [756] 33.75 [857] 35.75 [908]
29.75 [756] 29.75 [756] 29.75 [756] 33.75 [857] 35.75 [908]
Height “H” inches [mm]
Length “L” inches [mm]
Width “W” inches [mm]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem A13 Series and is the answer not in the manual?

Rheem A13 Series Specifications

General IconGeneral
BrandRheem
ModelA13 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals