Triton Service Manual SVC1020T ; Rev 4
80 and 100 gallon chassis
Troubleshooting Error Codes
43
T123 thru T137 Anode Alerts
Anode locations indicated below.
Refer to next 2 pages for troubleshooting instructions.
Locate the anode control module at the top of the unit. If the
LED light on top of the module is GREEN then the anodes are
still protecting the tank.
Confirm both wiring harnesses are securely connected to
anode control module and no signs of damage to wiring.
If both harnesses are secure and LED on anode module is
not green, anode module needs to be replaced.
If anode module LED is green, confirm wiring harness at
the P8 connector on ignition board is secure and no signs
of damage. If this checks good, cycle power. If issue
persists replace ignition control board.
Error T122 No Communication with Powered Anode Controller for >60 seconds.