Numbers: [0-9] (10 digits)
Symbols: SP (spaces) ! " # $ % & ' ( ) * + , - . / : ; < = > ? @ [ \ ] ^ _ ` { | } ~ (33 symbols)
(2) Registerable password length:
For general users
No fewer than the Minimum Password Length specified by the user administrator (8-32
characters) and no more than 128 characters.
For administrators and a supervisor
No fewer than the Minimum Password Length specified by the user administrator (8-32
characters) and no more than 32 characters.
(3) Rule:
Passwords that are composed of a combination of characters based on the Password
Complexity Setting specified by the user administrator can be registered. The user
administrator specifies either Level 1 or Level 2 for Password Complexity Setting.
FIA_UAU.2 User authentication before any action
Hierarchical to: FIA_UAU.1 Timing of authentication.
Dependencies: FIA_UID.1 Timing of identification.
FIA_UAU.2.1 The TSF shall require each user to be successfully authenticated before allowing any other
TSF-mediated actions on behalf of that user.
FIA_UAU.7 Protected authentication feedback
Hierarchical to: No other components.
Dependencies: FIA_UAU.1 Timing of authentication.
FIA_UAU.7.1 The TSF shall provide only [assignment: displaying a dummy letter (*: asterisks, or ?:
bullets) for one letter of passwords on authentication feedback] to the user while the
authentication is in progress.
FIA_UID.2 User identification before any action
Hierarchical to: FIA_UID.1 Timing of identification.
Dependencies: No dependencies.
FIA_UID.2.1 The TSF shall require each user to be successfully identified before allowing any other
TSF-mediated actions on behalf of that user.
FIA_USB.1 User-subject binding
Hierarchical to: No other components.
Dependencies: FIA_ATD.1 User attribute definition.
FIA_USB.1.1 The TSF shall associate the following user security attributes with subjects acting on the
behalf of that user: [assignment: general user IDs, document data default ACL,

Table of Contents

Other manuals for Ricoh Gestetner MP 4001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Gestetner MP 4001 and is the answer not in the manual?

Ricoh Gestetner MP 4001 Specifications

General IconGeneral
BrandRicoh
ModelGestetner MP 4001
CategoryAll in One Printer
LanguageEnglish

Related product manuals