Technical Bulletin PAGE: 8/11
Reissued: 26-Dec-16
Modified Points or Symptom Corrected
first, in cases where EQ and normal authentication logins are performed at the same
time.
- The machine may not accept incoming data after a Cheetah remote F/W update is
performed.
- The Copier function is not available if a copy job originates from Rimoco.
Other changes:
1. Supports Web application API V1.02.
Firmware modification (Engine and System/Copy) so that the power line (24V) is shut
down when detecting the layer short-circuit and SC code is displayed.
Note:
SC666 has been newly added. Depending on the sub code of SC666, the action is
different as follow.
SC666-01 :PCB:IOB:ENGINE
SC666-02/03 :PCB:IOB:TRANSPORT
SC666-00 :Both PCB:IOB:ENGINE and TRANSPORT
IMPORTANT: To apply the above changes, update this firmware together with Engine
V1.29:08 (D1475503) or newer.
1. SC998 occurs when the machine returns to normal (standby) mode.
2. An email is not cancelled if an alert occurs while it is being composed and the alert is
then cleared.
3. A memory leak occurs while the Web API is being used.
4. A 128-byte User ID that is used to login to the Web UI is shortened to 32 bytes.
5. A 128-byte password is truncated to 32 bytes when stored in the Address Book (Web
API).
6. A UI customized app shuts down when the user logs in using the Web API
Authentication UI Customization function.
7. Two notification screens are displayed when logout fails.
8. The notification screen for when IC card login (with a PIN) fails is not displayed when
using a UI customized app.
9. A memory leak occurs if the authentication request sent to the authentication logic
customized app. times out.
10. SOP apps cannot be installed correctly.
11. Multi-byte User IDs sent to the SOP may appear as garbled characters.
Other changes:
1. Supports Web application API V1.01.
1. Supports CDN (Contents Delivery Network).
Symptom corrected:
1. Machine cannot recover from Energy Saver mode.
2. SC672-11 (Controller start up error) occurs when the machine is prompted (e.g. by a
print job or other operation) to recover from Energy Saver mode.
3. SC899 occurs if the main power switch is turned off before the application has