RIGOL Chapter 6 MATH and Measurement
6-28 MSO1000Z/DS1000Z User’s Guide
Delay and Phase
Source1
Period
Delay
Source2
Figure 6-4 Delay and Phase
Source 1 and source 2, the same as source A and source B in the measurement
setting menu can be any channel of CH1-CH4 or D0-D15. For the setting method,
please refer to the introduction in "Measurement Setting
".
1. Delay 12: the time difference between the rising edges of source 1 and
source 2. Negative delay indicates that the selected rising edge of source 1
occurred after that of source 2.
2. Delay 12: the time difference between the falling edges of source 1 and
source 2. Negative delay indicates that the selected falling edge of source 1
occurred after that of source 2.
3. Phase 12: phase difference calculated according to "Delay 12" and
the period of source 1, expressed in degree. The calculation formula is as shown
in equation
(6-1).
4. Phase
12: phase difference calculated according to "Delay 12" and
the period of source 1, expressed in degree. The calculation formula is as shown
in equation
(6-1).
The phase calculation formula:
×360
Delay
Phase =
Period1
°
(6-1)
Wherein,
Phase
represents "Phase 12" or "Phase 12"
Delay
represents "Delay 12" or "Delay 12"
1Period
represents the period of source 1
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Other manuals for Rigol MSO1104Z

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol MSO1104Z and is the answer not in the manual?

Rigol MSO1104Z Specifications

General IconGeneral
BrandRigol
ModelMSO1104Z
CategoryTest Equipment
LanguageEnglish

Related product manuals