Chapter 7 Digital Channel RIGOL
MSO1000Z/DS1000Z User’s Guide 7-1
Chapter 7 Digital Channel
MSO1000Z provides 4 analog channels as well as 16 digital channels. DS1000Z Plus
can be upgraded to MSO using the MSO upgrade option. For the digital channels, the
oscilloscope compares the voltages acquired in each sample with the preset logic
threshold. If the voltage of the sample point is greater than the logic threshold, it will
be stored as logic 1; otherwise, it will be stored as logic 0. The oscilloscope displays
the logic 1 and logic 0 in figure form for users to easily detect and analyze the errors
in circuit design (hardware design and software design). This chapter introduces how
to use the digital channels of the mixed signal digital oscilloscopes.
Before using the digital channels, connect the oscilloscope and the device under test
using RPL1116 logic probe provided in the accessories. For the using method of the
logic probe, refer to the
RPL1116 Logic Probe User’s Guide
.
Note: The digital channel input terminal does not support hot plug. Please do not
insert or pull out the logic probe when the instrument is powered on.
The contents of this chapter:
To Select the Digital Channel
To Turn on/off the Digital Channel
Group Set
To Set the Waveform Display Size
Reorder Setting
Auto View
To Set the Threshold
To Set the Label
Probe Calibration
Digital Channel Delay Calibration