H2 Series
12
3.5 Datasheet
Model
H2-5K-S3
H2-6K-S3
H2-7K-S3
H2-8K-S3
H2-10K-S3-A
H2-10K-S3
DC Input
Max. PV Array Power [Wp]@STC
7500
9000
10500
12000
15000
15000
Max. DC Voltage [V]
600
MPPT Voltage Range [V]
90~550
Rated DC Voltage [V]
360
Start Voltage/Min Input Voltage [V]
100
Max. DC Input Current [A]
16/16/16
Max. DC Short Circuit Current [A]
19.2/19.2/19.2
No. of MPPT
3
Battery Parameters
Battery Type
LiFePO4
Battery Voltage Range [V]
85~450
Max. Charging/Discharging Current [A]
50/50
AC Output [On-grid]
Rated AC Power [W]
4999
6000
7000
8000
9999
10000
Rated Apparent Power [VA]
4999
6000
7000
8000
9999
10000
Max. Apparent Power [VA]
4999
6600
7700
8800
9999
10000
Rated AC Output Current [A]
21.7
26.1
30.5
34.8
43.5
43.5
Max. AC Output Current to Utility Grid [A]
21.7
28.7
33.5
38.3
43.5
43.5
Current Inrush[A]
150
Max. AC Fault Current[A]
120
Max. AC Over Current Protection[A]
63
75
88
100
100
100
Rated AC Voltage/Range [V]
L+N+PE, 220, 230, 240/180~280
Rated Output Frequency/Range [Hz]
50,60/45~55,55~65
Power Factor [cos φ]
0.8 leading0.8 lagging
Total Harmonic Distortion [THDi]
<3%
AC Input [On-grid]
Rated AC Voltage/Range [V]
L+N+PE, 220, 230, 240/180~280
Rated Input Frequency [Hz]
50,60
Max. Input Current [A]@230Vac
43.5
52.2
60.9
69.6
69.6
69.6
AC Output [Back-up]
Max. Output Power [VA]
4999
6000
7000
8000
9999
10000
Model
H2-5K-S3
H2-6K-S3
H2-7K-S3
H2-8K-S3
H2-10K-S3-A
H2-10K-S3
Max. Output Current [A]
21.7
26.1
30.5
34.8
43.5
43.5
Peak Output Apparent Power [VA]
6000,60s
7200,60s
8400,60s
9600,60s
12000,60s
12000,60s
Rated AC Voltage/Range [V]
L+N+PE, 220, 230, 240/180~280
Rated Output Frequency/Range [Hz]
50,60/4555,5565
Output THDv (@ Linear Load)
<3%
Efficiency
Max. Efficiency
97.6%
Euro Efficiency
97.0%
Protection
Battery Input Reverse Polarity Protection
Integrated
Over Load Protection
Integrated
AC Short Circuit Current Protection
Integrated
DC Surge Protection
Integrated
AC Surge Protection
Integrated
Anti-islanding Protection
AFD
AFCI Protection
Optional
RSD Protection
Optional
Interface
PV Connection
MC4/H4(Optional)
AC Connection
Plug-in connector
Battery Connection
Quick connector
Display
LED+APP
Communication
Wi-Fi/Ethernet/4G(Optional)
General Parameters
Topology
Non-isolated
Operating Temperature Range
-40 to +60 (45 and above with derating)
Cooling Method
Natural Convection
Ambient Humidity
0-100% Non-condensing
Altitude
4000m (>3000m Power Derating)
Noise [dBA]
<35
Ingress Protection
IP65
Dimensions [H*W*D] [mm]
430.5* 549 *223
Weight [kg]
26
Warranty [Year]
Refer to the warranty policy
Standard
CEI 0-21, VDE4105-AR-N, VDE0126-1-1, EN50438, G98, G99, EN50549, AS4777.2, IEC62109-1&-2, IEC62040-1 ,
EN61000-6-1/2/3/4