H2 Series
24
Figure 5.2
Connecting the additional
grounding cable
5.2 AC Grid Wire and Backup Output Connection
Cable cross-sectional areamm²)
Range
Recommend
13~21
16
Additional grounding cable cross-sectional area (m): 6
Table 5.1
Recommended specifications of AC cables
Note: If the grid-connection distance is too far, please select an AC cable with larger diameter as per the
actual condition.
Procedure:
Step 1: Open the waterproof cover, feed the AC cable through the AC waterproof hole.
Figure 5.3
Thread the cables
Step 2: Fix the cables according to conductor marks of L, N and PE.
Figure 5.4
Connect the Cables