EasyManuals Logo
Home>SAJ>Inverter>R6 Series

SAJ R6 Series User Manual

SAJ R6 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
R6 Series
- 20 -
AFCI Protection
Optional
Interface
AC Connection
Terminal Block
DC Connection
MC4
Display
LED+APP (Bluetooth
Communication Port
RS232+RS485 (RJ45)+DRM(RJ45)
Communication Mode
Wi-Fi/Ethernet//4G
Load Monitoring
24/7 (Optional)
General Data
Topology
Transformerless
Nighttime Power Consumption [W]
<0.6
Operating Temperature Range
-40℃+60℃
Cooling Method
intelligent fan Cooling
Ambient Humidity
0%100% non-condensing
Max. Operating Altitude [m]
3000m
Noise [dBA]
<50
Ingress Protection
IP65
Mounting
Rear Panel
Dimensions [H*W*D] [mm]
659.4*473*240
Weight [kg]
35.5
37.5
Warranty [Year]
5 (Standard)/10/15/20/25 (Optional)
Certifications
IEC/EN62109-1/2, EN61000-6-1/2/3/4, IEC61683, IEC60068-2, IEC62116,
IEC61727, PEA/MEA,VDE0126-1-1/A1, CEI 0-21, VDE-AR-N 4105,
AS/NZS4777.2, CQC NB/T 32004, G98/G99, NBR 16149, NBR 16150,
C10/11,RD1669,UNE206006, UNE206007,EN50438
Note: *1. According to C10/C11, Max. AC Power = Rated AC Power
2. The above parameters might be slightly modified according to different grid codes.
3. If you need more information about our product certifications, please contact our sales.

Questions and Answers: