14 І 56
Installing the plastic extension tubes, suction
hose and oor nozzle (g. 13)
Assemble the plastic extension tubes (20) by pushing
them together. Connect the assembled plastic exten-
sion tubes with the bent end of the suction hose (14).
Fit the oor nozzle (18) or joint nozzle (19) to the other
end of the assembled plastic extension tubes.
Installing the bottom cable holder (g. 2+14)
Clip the bottom cable holder (20) onto the wheel
mounting base at the rear of the device. The top ca-
ble holder (7) is on the connection port for the blower
function (12).
8. Operation
m WARNING!
Switch the device off if liquid or foam emerges with
the exhaust air during wet vacuuming.
Switching on/off (g. 15)
The on/off switch (11) has two settings
• Switch setting 0: Off
• Switch setting I: On
Press the on/off switch (11) to switch on. Switch set-
ting I: On
Press the on/off switch (11) again to switch the device
off. Switch setting 0: Off
Dry vacuuming (g. 3+9)
Use the folded lter (18) for dry vacuuming. The pa-
per lter bag (17) can be used in addition. This en-
sures that the folded lter (18) remains free of dust for
longer and maintains the vacuum power for longer.
In addition, the disposal of the dust is also easier.
Always ensure that the lters are correctly tted.
Wet vacuuming (g. 3+8)
Use the foam lter (16) for wet vacuuming. Ensure
that the foam lter (16) is correctly tted.
If the stainless steel container (9) is full, the safety
oat valve (14) closes the suction port and suction
operation is interrupted.
m IMPORTANT!
The device is not suitable for vacuuming ammable
liquids. For wet vacuuming, use the only the foam lter
(16) provided. To remove the liquid vacuumed up from
the stainless steel container, take off the machine head
(2) by releasing the locking hooks (4) from the stainless
steel container (9). Pour out the liquid residue.
Installing the castor mounts (g. 4+5)
1. Turn the stainless steel container (9) upside-down
(the machine head (2) must be removed).
2. Push the castor mounts (5) into the cut-outs provi-
ded on the wheel mounting base (7). (4x)
3. Fasten the castor mounts (5) with a screwdriver
(not included in the delivery) and one screw each
(20). (4x)
Installing the castors (g. 6)
1. Press the four castors (6) into the holes in the
castor mounts (5).
Installing the machine head (2) and the handle (1)
(Fig. 7)
1 Place the machine head (2) on the stainless steel
container (8). Secure the machine head (2) with
the locking hooks (4). When installing the machine
head (2), ensure that the locking hooks (4) latch into
place correctly.
2 Place the handle (1) on the machine head (2) and
fasten it with two screws (21) with a screwdriver
(not included in the delivery).
Installing the foam lter (15) (g. 3+8)
Never use the device without lter! Always ensure
that the lters are correctly tted!
Installing the foam lter (15): For wet vacuuming, slide
the foam lter (15) provided over the lter basket with
safety oat valve (13).
Installing the folded lter (17) (g. 3+9)
For dry vacuuming, slide the folded lter (17) provided
over the lter basket with safety oat valve (13). The
folded lter (17) is only suitable for dry vacuuming!
Installing the paper lter bag (16) (g. 3+10)
It is recommended to use an additional paper lter
bag (16) when vacuuming ne, dry dirt. Slide the
paper lter bag (16) over the suction opening in the
stainless steel container (9). The paper lter bag (16)
is only suitable for dry vacuuming. The paper lter
bag (16) makes it easier to dispose of the dust col-
lected.
Installing the suction hose (g. 11 + 12)
Connect the suction hose (14) to the corresponding
port, depending on the desired use, on the wet and
dry vacuum.
Vacuuming:
Connect the suction hose (14) to the suction hose
port (9). To do so, slide the end of the suction hose
(14) with the two nipples into the suction hose port (9)
(A). Insert the two nipples into the recesses. Once
the suction hose is fully inserted, turn it clockwise (B).
Blowing:
Connect the suction hose (14) to the suction hose
port (12). Slide the end of the suction hose (14) with
the two nipples into the blowing function connection
port (12). Insert the two nipples into the recesses. It is
not necessary to turn it here.