If the carbon is worn to a length of 6 mm, or if the spring
or contact wire are burned or damaged, it is necessary
to replace both brushes. If the brushes are found to
be usable following removal, it is possible to reinstall
them.
When servicing the carbon brushes, open the two lat-
ches counterclockwise (as shown in Figure 21). Then
remove the carbon brushes.
Replace the carbon brushes in the reverse order.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles.
Wear parts*: carbon brushes, saw blade, table inserts,
sawdust bags
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
11. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and
30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
12. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomers mains connection as well as the extensi-
on cable used must also comply with these regu-
lations.
Important information
In the event of an overloading the motor will switch it-
self o󰀨. After a cool-down period (time varies) the mo-
tor can be switched back on again.
9. Transport
Tighten the handle (11) to lock the rotary table.
Press the machine head (4) downwards and secure
with the locking bolt (23).
Fix the saw’s drag function with the locking screw for
drag guide (20) in rear position.
Carry the equipment by the xed saw table (15).
When reassembling the equipment proceed as de-
scribed under section 7.
10. Maintenance
m WARNING! Prior to any adjustment, maintenance
or service work disconnect the mains power plug!
General maintenance measures
Wipe chips and dust o󰀨 the machine from time to time
using a cloth. In order to extend the service life of the
tool, oil the rotary parts once monthly. Do not oil the
motor.
When cleaning the plastic do not use corrosive pro-
ducts.
Cleaning the moving saw blade guard safety de-
vice (5)
Always check the saw blade guard for debris before
using the machine.
Remove old sawdust and splinters using a brush or si-
milar tool.
Replacing the table insert
Danger!
With a damaged table insert (10) there is a risk of
small parts getting stuck between table insert and
saw blade, blocking the saw blade. Immediately re-
place damaged table inserts!
1. Remove screws at table insert. If required, turn ro-
tary table and incline saw head to be able to reach
the screws.
2. Remove table insert.
3. Install new table insert.
4. Tighten the screws at table insert.
Brush inspection
Check the carbon brushes after the rst 50 operating
hours with a new machine, or when new brushes have
been tted. After carrying out the rst check, repeat the
check every 10 operating hours.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach HM254 and is the answer not in the manual?

Scheppach HM254 Specifications

General IconGeneral
Laser guideYes
Product colorBlue, Grey
Sliding rails-
Number of blade teeth60
Input power2000 W
Power sourceAC
AC input voltage220 - 240 V
AC input frequency50 Hz
Idle speed (max)- RPM
Cutting width (90°)340 mm
Weight and Dimensions IconWeight and Dimensions
Depth820 mm
Width480 mm
Height410 mm
Weight17560 g