2. Unscrew the spark plug and check it.
3. If there is any damage, e.g. cracks or chips, re-
place the spark plug.
4. Clean the spark plug electrodes with a wire brush.
5. Check and set the electrode gap.
6. Screw the spark plug in and tighten with the spark
plug spanner.
7. Place the spark plug connector (f) on the spark
plug.
When replacing, ensure that no dirt gets into the cyl-
inder head.
Check the t of the spark plug.
A loose spark plug can cause damage to the engine by
overheating. Pulling too hard can damage the thread
in the cylinder head.
The manufacturer is not responsible for the resulting
damages; the user solely bears the risk. Only use the
recommended spark plugs or identical spark plugs.
Clean the air lter (g. 1 + 9)
1. Loosen the knurled screw (7)
2. Remove the air lter cover (5).
3. Clean the foam pre-lter (e) a non-ammable
solvent.
Attention:Do not use petrol or cleaning solvents with a
low ash point to clean the airlter element. This could
result in re or explosion.
4. Squeeze the pre-lter in order to remove the sol-
vent/soapy water.
5. Rinse the washed lter element with clean water.
6. Allow the lter element to dry thoroughly or blow
it out.
7. Attach the lter cover again and tighten the
knurled screw.
If the engine is operated in very dusty environments,
clean the air lter daily or after every ten operating
hours.
Never run the engine without an airlter or with a dam-
aged air lter. This would allow dirt into the engine,
which would result in severe damage to the engine.
The manufacturer is not responsible for the resulting
damages; the user solely bears the risk.
Important note in the case of repairs:
When returning the device for repair, please ensure for
safety reasons that it is free of oil and fuel when it is
sent to the service centre.
8. The unit may not be stored in the open.
9. Cover the unit and the engine to protect against
dust and store in a clean, dry place.
When re-commissioning after a long period of storage
1. Change the engine oil.
2. Fill with fresh petrol before starting the motor after
the storage period.
If the engine is not used for more than one month,
changes to the petrol quality may result in di󰀩culties
starting the engine or in other issues. To prevent this,
loosen the carburettor’s drain screw and allow the
petrol to run out. Also open the fuel valve so that the
petrol drains from the tank.
13. Maintenance
Attention!
Always shut the engine down and remove the spark
plug connector before carrying out any maintenance
work.
Changing the oil (g. 8)
Change the engine oil after 25 operating hours, then
after 50 hours or every three months.
Drain the engine oil when the engine is hot.
1. Warm the engine up.
2. Switch the engine o󰀨.
3. Place a container that is large enough to collect
the used oil under the oil drain screw (c).
4. To drain the oil, remove the screw-on oil cap (10)
and the oil drain screw (c).
5. Drain the oil
6. Re-attach the oil drain screw (c) with a sealing
washer and tighten.
7. Pour the recommended engine oil into the oilller
hole.
Note! Tightly screw the oil ller cap with dipstick (10).
Capacity: approximately 0.6 litres Dispose of the
drained oil properly at a local used oil collection point.
Dumping used oil in the soil or mixing it with waste is
prohibited.
Check the spark plug (g. 10)
Switch o󰀨 the engine and allow it to cool. Caution!
Danger of burning Clean or replace spark plug as re-
quired:
1. Remove the spark plug connector (f) and clean
any dirt from the spark plug area.