6
CX34K3
6-1 6-2
MCL1 MCL2
CH-No. Fv (MHz) SOUND SYS CH-No. Fv (MHz) SOUND SYS
0 0 590.25 B/G
1 48.25 B/G 1 46.25 B/G
2 62.25 B/G 2 64.25 B/G
3 77.25 D/K 3 86.25 B/G
4 175.25 B/G 4 95.25 B/G
5 182.25 B/G 5 138.25 B/G
6 183.25 D/K 6 175.25 B/G
7 191.25 D/K 7 182.25 B/G
8 196.25 B/G 8 189.25 B/G
9 199.25 M 9 196.25 B/G
10 210.25 B/G 10 209.25 B/G
11 224.25 B/G 11 216.25 B/G
12 471.25 B/G 12
13 487.25 I 13
14 503.25 B/G 14
15 575.25 B/G 15
16 583.25 B/G 16
17 599.25 B/G 17
18 621.25 M 18 527.25 B/G
19 639.25 D/K 19 847.25 B/G
20 703.25 B/G 20 48.25 B/G
21 735.25 I 21 175.25 B/G
22 767.25 B/G 22 210.25 B/G
23 815.25 B/G 23 224.25 B/G
24 855.25 I 24 575.25 B/G
25 855.25 B/G 25 599.25 B/G
26 55.25 M 26 767.25 B/G
27 83.25 M 27 183.25 M
28 183.25 M 28 193.25 M
29 193.25 M 29 112.25 B/G
30 217.25 M 30 168.25 B/G
31 471.25 M 31
32 477.25 M 32 294.25 B/G
33 693.25 M 33 463.25 B/G
34 34 174.95 B/G
35 112.25 B/G 35 175.55 B/G
36 168.25 B/G 36
37 37 599.25 B/G
38 294.25 B/G 38
39 463.25 B/G 39
40 40
41 647.25 B/G 41
42 663.25 B/G 42
43 679.25 B/G 43
44 174.95 B/G
45 175.55 B/G
INITIAL SETTING
(1)In service mode, After execute select POS 1, store the following tuning data in E
2
PROM.
SHIPPING SETTING & CHECKING
(1)The following default data has been factory-set for the E
2
PROM.
ITEMS DATA SETTING
LAST PROGRAM/CHANNEL 1
FLASHBACK PROGARM/CH 1
DIGIT 1
C-SYSTEM AUTO
S-SYSTEM *1
SKIP OFF
AFC ON
VOLUME 1
CONTRAST 60 (MAX)
COLOUR 0 (CENTER)
BRIGHTNESS 0 (CENTER)
TINT 0 (CENTER)
SHARPNESS 0 (CENTER)
WHITE TEMP STANDARD
REMINDER TIMER In-active, "--:--"
ON TIMER In-active, "--:--"
OFF TIMER In-active, "--:--"
LAST POWER POWER-ON
LANGUAGE ENGLISH
BLUE BACK MUTE OFF
HOTEL MODE OFF
0 CHANNEL SKIP ON
After pressing "MODEL SETTING", 0 Channel will be skipped.