Device Management
3.2Configuring the Device
The following is the pin-out for the port:
Figure3.1 Serial DB9 Console Port
Pin Name Description
1
a
Reserved (Do Not Connect)
2 TX Transmit Data
3 RX Receive Data
4
a
Reserved (Do Not Connect)
5 GND Signal Ground
6
a
Reserved (Do Not Connect)
7
b
Reserved (Do Not Connect)
8
b
Reserved (Do Not Connect)
9 Reserved (Do Not Connect)
a
Connected internally.
b
Connected internally.
Communication Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RS900G console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RS900G is
https://192.168.0.1.
For more information about available ports, refer to "Communication Ports (Page
19)".
3.2 Configuring the Device
Once the device is installed and connected to the network, it must be configured. All
configuration management is done via the RUGGEDCOM RS900G interface. For more
information about configuring the device, refer to the RUGGEDCOM RS900G User
Guide associated with the installed software release.
18
RUGGEDCOM RS900G
Installation Manual, 01/2021, C79000-G8976-1025-08