Chapter 4
Technical Specifications
Fiber Optic Ethernet Port Specifications 23
Tx (dBm)
Mode
Connector
Type
Tx λ (nm)
i
Cable
Type (μm)
Minimum Maximum
Rx
Sensitivity
(dBm)
Rx
Saturation
(dBm)
Distance
(km)
i
Power
Budget
(dB)
62.5/125 -19 -14 -33.5 -14 2 14.5
50/125 -22.5 -14 -33.9 -14 2 11.4
MM SC 1300
62.5/125 -19 -14 -33.9 -14 2 14.9
50/125 -22.5 -14 -33.9 -14 2 11.4
MM ST 1300
62.5/125 -19 -14 -33.9 -14 2 14.9
MM LC 1310 62.5/125 -19 -14 -32 -14 2 13
SM ST 1310 9/125 -15 -7 -34 -3 20 19
SM LC 1300 9/125 -15 -8 -38 -3 20 23
SM LC 1310 9/125 -5 0 -35 -3 50 30
SM LC 1310 9/125 0 5 -37 0 90 37
SM SC 1300 9/125 -15 -8 -31 -7 20 16
SM SC 1310 9/125 -5 0 -34 -3 50 29
SM SC 1310 9/125 5 0 -37 0 90 42
62.5/125 -19 12
MM ST
50/125
1300
-22.5
-14 -31 -14 2
8.5
62.5/125 -19 12
MM SC
50/125
1300
-22.5
-14 -31 -14 2
8.5
MM MTRJ 62.5/125 1300 -19 -14 -31 -14 2 12
SM ST 9/125 1300 -15 -8 -32 -3 20 17
SM SC 9/125 1300 -15 -8 -31 -7 20 16
SM LC 9/125 1300 -15 -8 -34 -7 20 19
SM SC 9/125 1300 -5 0 -34 -3 50 29
SM LC 9/125 1300 -5 0 -35 3 50 30
SM SC 9/125 1300 0 5 -37 0 90 37
SM LC 9/125 1300 0 5 -37 0 90 37
MM LC 50/125 1300 -22.5 -14 -31 -14 2 8.5
i
Typical.