Certification
6.1.2CSA/Sira
• ANSI/UL 60079-15:13
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection
"n"
The device is marked with a CSA symbol that indicates compliance with both
Canadian and U.S. requirements.
It is specifically approved for use in Division 2 and Zone 2 hazardous locations with
the following markings:
• Class I, Division 2, Groups A, B, C, D T4
• Ex nA nC IIC T4 Gc
• Class I, Zone 2, AEx nA nC IIC T4 Gc
This device meets the requirements of the following International standards under
certificate IECEx CSA 18.0007X:
• IEC 60079-0:2011
Explosive Atmospheres – Part 0: Equipment – General Requirements
• IEC 60079-15:2010
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test
and Marking of Type of Protection "n" Electrical Apparatus.
It is specifically approved for use in Zone 2 hazardous locations with the following
markings:
• Ex nA nC IIC T4 Gc
6.1.2 CSA/Sira
When marked with the following ATEX marking, this device is approved for use in
Zone 2 hazardous locations under certificate Sira 18ATEX4069X.
Note
For the maximum ambient temperature, refer to the hazardous location label affixed
to the device.
The device also meets the requirements of the following European directive and
standards:
38
RUGGEDCOM RSG909R
Installation Manual, 02/2021, C79000-G8976-1388-12