Description of the device
3.3 LED display
SCALANCE XR-300WG
Operating Instructions, 05/2017, C79000-G8976-C454-01
21
3.2.2
Device view of 240 VAC variant
The following figure shows an overview of the components of a 240 VAC variant of a
SCALANCE XR-300WG based on the example of a SCALANCE XR328-4C WG.
Electrical ports with port LEDs
Combo port ports with port LEDs
Integrated brackets for 19" rack mounting
240 V AC power supply (rear)
Grounding screw
Serial interface
"RESET" button
LED display
The "F" LED for faults
The "RM" LED for the redundancy manager function
LED "L" for the power supply
3.3
LED display
3.3.1
Fault LED "F"
The fault LED "F" indicates the incorrect functioning of the device.
LED color
LED status
Meaning
- Off The device is switched off or has not detected a prob-
lem.
Red Lit The device has detected a problem.
Using the WBM and CLI, you can set when the device
signals an error and which errors should be signaled.