Description of the device
3.5 Combo ports
SCALANCE XR-300WG
Operating Instructions, 05/2017, C79000-G8976-C454-01
25
3.5
Combo ports
Characteristics
Combo port is the name for two communication ports. A combo port has the two following
jacks:
a fixed RJ-45 port
an SFP transceiver slot that can be equipped individually
Of these two ports, only one can ever be active. Using the mode, you can decide how the
ports are prioritized.
The port name is the same on both jacks of the combo port, for example "PxC".
There is an LED for each plug-in slot. The LEDs for the RJ-45 ports are located directly at
the ports. THE LEDs for the pluggable transceiver slots are located to the right and labeled
with the port name "PxC"
Setting the mode
The following modes can be configured for a combo port:
Mode 1:
auto
The SFP transceiver port has priority. As soon as an SFP transceiver is plugged in, an
existing connection at the fixed RJ-45 port is terminated. If no SFC transceiver is plugged
in, a connection can be established via the fixed RJ-45 port.
Mode 2:
rj45
The fixed RJ-45 port is independent of the SFP transceiver port.
Mode 3:
sfp
The pluggable transceiver port is used independent of the fixed RJ-45 port.
The factory setting for the combo ports is mode 1: auto
You configure the mode with Web Based Management or the Command Line Interface.