Technical specifications
7.2 Technical specifications of the SCALANCE XR328-4C WG
SCALANCE XR-300WG
52 Operating Instructions, 05/2017, C79000-G8976-C454-01
Technical specifications
Fusing 5 A / at least 60 V
Or power supply with LPS or NEC class 2
Current consumption
500 mA
Effective power loss
12 W
Permitted ambient conditions
Ambient temperature
1)
During operation up to 3000 m
0 ℃ to +60 ℃
During storage
-40 ℃ to +85 ℃
During transportation
-40 ℃ to +85 ℃
Relative humidity
During operation at 25 ℃
≤ 95 % no condensation
Housing, dimensions and weight
Design
Rack
Housing material
Metal
Degree of protection
IP30
Dimensions (W x H x D)
482.6 x 43.6 x 127 mm
Weight
2800 g
Installation options
19" rack mounting
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
> 43 years
1)
Depending on which pluggable transceiver you use, the maximum ambient temperature
can change, see section "Accessories (Page 19)".