Technical specifications
4.2 Technical data
IOT2000 Extension Modules
Operating Instructions, 2018/05, A5E39456816-AB
27
WEEE label (European Union)
Disposal instructions, observe the local regulations and the section "Recycling and
disposal
(Page 15) ".
4.2
Technical data
The IOT2000 Extension Modules are designed for IOT2000. When IOT2000 Extension
Modules work with IOT2000, the following technical specifications of the whole device are
the same with IOT2000:
Degree of protection: IP20 according to IEC 60529;
Electromagnetic compatibility;
Ambient conditions.
For the detail technical specification, refer to the chapter
"Technical data"
in
SIMATIC
IOT2020, SIMATIC IOT2040 Operating Instructions.
4.2.1
IOT2000 Input/Output Module
IOT2000 Input/Output Module
MLFB
6ES7647-0KA01-0AA2
Digital inputs
Number 5
Electrical isolation
Yes
Number of high speed inputs
0
Input frequency
Normal input
High speed input
Max. 20 Hz
--
Max. continuous permissible voltage
28.8 VDC
Input voltage
Signal 0
Signal 1
< 5 VDC
> 12 VDC
Input current at
Signal 0
Signal 1
< 1.0 mA
> 2.1 mA
Delay time at
0 to 1
1 to 0
Typ. 1.5 ms
Typ. 15 ms
Line length (unshielded)
Max. 100 m

Other manuals for Siemens SIMATIC IOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IOT2000 Series and is the answer not in the manual?

Siemens SIMATIC IOT2000 Series Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IOT2000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals