Technical specifications
4.2 Technical data
IOT2000 Extension Modules
30 Operating Instructions, 2018/05, A5E39456816-AB
4.2.3
Hardware Interface
4.2.3.1
Hardware Interface for IOT2000 Input/Out Module
You can control the I/O state by the user application port as shown below.
Description
Function
User application port
Inter-Connection
DI0
Digital Input
D12
PB4
DI1 D11 PB3
DI2
D10
PB2
DI3
D9
PB1
DI4
D4
PD4
DQ0 Digital Output D8 PB0
DQ1
D7
PD7
U0
Analog Input
A0
PC0
I0
A1
PC1
U1 A2 PC2
I1
A3
PC3
M
M
P5V
P5V
P24V
P24V