Description of the device
4.5 LED display
SCALANCE SC-600
Operating Instructions, 10/2021, C79000-G8976-C453-04
33
Meaning in display mode B
In display mode B, the port LEDs indicate the transmission speed.
LED color
LED status
Meaning
-
Off
Port operating at 10 Mbps
Green
On
Port operating at 100 Mbps
Orange
On
Port operating at 1000 Mbps
If there is a connection problem and the type of transmission is fixed (autonegotiation
off), the desired status, in other words the set transmission speed (1000 Mbps, 100
Mbps, 10 Mbps) continues to be displayed. If there is a connection problem and
autonegotiation is active, the port LED goes off.
Meaning in display mode C
In display mode C, the port LEDs indicate the mode.
LED color
LED status
Meaning
-
Off
Port operating in half duplex mode
Green
On
Port operating in full duplex mode
Meaning in display mode D
In display mode D, the port LEDs indicate whether the port is monitored.
LED color
LED status
Meaning
-
Off
Port is not monitored.
If no link was established at the port the signaling
contact does not indicate an error.
Green
On
Port is monitored.
If no link was established at the port the signaling
contact indicates an error.

Other manuals for Siemens SIMATIC NET SCALANCE SC-600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE SC-600 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE SC-600 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE SC-600
CategorySwitch
LanguageEnglish

Related product manuals