Error Codes of Alarm 300500 08/2005
4-986
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
Extension 2 -
Explanation Performance 1 and standard cannot run two axes with HSA.
Remedy Only one HSA axis may be active.
Error code 0048H
Error text Unexpected measurement system configuration
Extension 1 -
Extension 2 -
Explanation The PCU extension for direct or indirect measurement systems is incomplete.
Remedy Check module.
Error code 0049H
Error text A CCU3 axis was defined as a single-axis model.
Extension 1 -
Extension 2 -
Explanation -
Remedy -
Error code 0050H
Error text Module not supported by drive software.
Extension 1 -
Extension 2 -
Explanation The drive software cannot be run on this module.
Remedy Load the drive software for the module or plug in the correct module for the drive soft-
ware.