1.5 Residual risks of power drive systems
When assessing the machine- or system-related risk in accordance with the respective local
regulations (e.g., EC Machinery Directive), the machine manufacturer or system installer must
take into account the following residual risks emanating from the control and drive components
of a drive system:
1. Unintentional movements of driven machine or system components during commissioning,
operation, maintenance, and repairs caused by, for example,
Hardware and/or software errors in the sensors, control system, actuators, and cables and
connections
Response times of the control system and of the drive
Operation and/or environmental conditions outside the speci󹪝cation
Condensation/conductive contamination
Parameterization, programming, cabling, and installation errors
Use of wireless devices/mobile phones in the immediate vicinity of electronic components
External in󹪞uences/damage
X-ray, ionizing radiation and cosmic radiation
2. Unusually high temperatures, including open 󹪞ames, as well as emissions of light, noise,
particles, gases, etc., can occur inside and outside the components under fault conditions
caused by, for example:
Component failure
Software errors
Operation and/or environmental conditions outside the speci󹪝cation
External in󹪞uences/damage
3. Hazardous shock voltages caused by, for example:
Component failure
In󹪞uence during electrostatic charging
Induction of voltages in moving motors
Operation and/or environmental conditions outside the speci󹪝cation
Condensation/conductive contamination
External in󹪞uences/damage
4. Electrical, magnetic and electromagnetic 󹪝elds generated in operation that can pose a risk to
people with a pacemaker, implants or metal replacement joints, etc., if they are too close
5. Release of environmental pollutants or emissions as a result of improper operation of the
system and/or failure to dispose of components safely and correctly
6. In󹪞uence of network-connected communication systems, e.g. ripple-control transmitters or
data communication via the network
For more information about the residual risks of the drive system components, see the
relevant sections in the technical user documentation.
Fundamental safety instructions
1.5Residual risks of power drive systems
ONE MCP Part 2: MCP 2200
12 Equipment Manual, 11/2022, A5E50324703B AC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2200 and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2200 Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2200
CategoryControl Systems
LanguageEnglish

Related product manuals