2. Applications
This product is intended for use in circuits that require low speed air supply to gradually raise
initial pressure in an air system and for quick exhaust by cutting off air supply when the control
power is cut off in the event of a power failure or emergency.
3. Specifications
Specifications
Solenoid Specifications
Series AV2000-A AV3000-A AV4000-A AV5000-A
Port size
1(P)2(A)
1/4 3/8 1/2 3/4 1
3(R) 1/4 3/8 1/2 3/4
Pressure gauge port size 1/8
Fluid Air
Ambient and fluid temperature
0 to 50
o
C *
1
(without solenoid valve: 0 to 60
o
C
*1
)
Proof pressure 1.5MPa
Operating pressure range 0.2 to 1.0MPa
Weight (kg) AV 0.43 0.45 0.80 1.30 1.25
AVA 0.43 0.45 0.80 1.32 1.27
AVL
(Manual operation)
0.62 0.64 0.99 1.51 1.46
AVL
(Manual operation
with solenoid valve)
0.67 0.68 1.03 1.55 1.50
Enclosure Dust-protected (DIN terminal and M12 connecter: IP65
*2
)
*1 If the temperature is low, use the product with dry air to prevent it from freezing.
*2 Based on IEC60529
Electrical entry Grommet DIN terminal M12 Connector
Rated coil voltage
[V]
DC 24, 12V
AC 50/60Hz 100, 200, 110[115], 220[230]
*1
Allowable voltage
fluctuation
DC
24V ±10% of the rated voltage
12V ±10% of the rated voltage
AC
100V ±10% of the rated voltage
110V
*1
[115V]
±10% of the rated voltage
[-15% to +5% of the rated voltage]
200V ±10% of the rated voltage
220V
*1
[230V]
±10% of the rated voltage
[-15% to +5% of the rated voltage]
Power
consumption [W]
DC 0.35 (With light: 0.4) 0.35 (With light: 0.45) With light: 0.4
Apparent power
[VA]
AC
100V 0.78 (With light: 0.81)
0.78 (With light: 0.87)
110V
*1
[115V]
0.86 (With light: 0.89)
[0.94 (With light: 0.97)]
0.86 (With light: 0.97)
[0.94 (With light: 1.07)]
200V 1.18 (With light: 1.22)
1.15 (With light: 1.30)
220V
*1
[230V]
1.30 (With light: 1.34)
[1.42 (With light: 1.46)]
1.27 (With light: 1.46)
[1.39 (With light: 1.60)]
Surge voltage suppressor Refer to the Specific Product Precautions on page 11 and 12
Indicator light LED LED (Neon bulb for AC)
LED
*1 The 110 VAC and 115 VAC are interchangeable. The 220 VAC and 230 VAC are interchangeable as well.