FLEXIBLE ASSEMBLY SYSTEM FAS200
User Manual for FAS200 - 15 -
pallet transfers are operated by a system of solenoid valves connected to each
module.
Figure 17: Stopper and lifter with microswitch and inductive detectors.
Both the pallet retention point and the relative position of the module within the
system FAS200 may be varied, making it simple to modify the distribution of the
component bases of the FAS-200. Although not recommended such
modifications as the system FAS200 is sent mechanically adjusted and
programmed to the specific distribution and any variation of the distribution
would also reprogram the control of the system.
TECHNICAL DATA: Modular transfer:
Dimensions (each transfer (for 4 modules)):
1 section 2000 x 130 mm. Height 970 mm.
Dimensions (each transfer (for 6 modules)):
1 section 2900 x 130 mm. Height 970 mm.
Drive (each transfer (for 4/6 modules)):
1 Motor 24 VDC HIWIN (AM1 M12029A1).
1 Power supply 24 VDC / 60 W OMRON (S8VK-G06024).
Composition:
Actuators (each 2 modules):
- 1 Compact double-acting cylinder Ø32, Stroke: 25mm (CQ2B32-25D-
XSE040). Controlled by 5/2 way monostable solenoid valve.