USE OF ADAPTORS, EXTENSIONS AND UNIVERSALS
Anytime an adaptor, extension or universal is used with a torque wrench in such a way that fastener
distance is different than torque wrench square drive distance at calibration, an adjustment to head
length is required to get a proper fastener torque reading.
When using wobble extension or a universal, do not exceed more than 15 degrees of offset from
perpendicular drive. Do not use a long extension with flex-drive at full flex.
CALIBRATION
Contact your Snap-on sales representative for calibration services.
CERTIFICATION
This TechAngle
®
Steel Micro wrench was calibrated at factory using torque measurement
instruments that are traceable to National Institute of Standards and Technology (N.I.S.T.). Torque
parameters comply with ISO 6789-2003 and ASME B107-28-2010. Note: no U.S. or International
Standards exist for angle wrenches. Angle calibration was performed on an angle gage with ±1
degree accuracy at each 45 degree indexing point throughout 180 degrees of rotation.
MAINTENANCE / SERVICE
Clean wrench by wiping with a damp cloth. DO NOT use solvents, thinners or carburetor cleaners.
DO NOT immerse in anything.
Service, repair and calibration are to be done by Snap-on Service Centers only. Contact your
Snap-on Tools representative. Ratchet head repair can be done by Snap-on Representative or user.
Battery Replacement
Replace with "AA" cell only.
o Do not attempt to recharge lithium cells.
o Store wrench in dry place.
o Remove battery when storing wrench unused longer than 3 months.
Note: When replacing battery, real-time-clock will maintain date and time for 20 minutes.
Note: Turn End Cap counter-clockwise to unscrew.