Slacken off the screws.
- Pull the wires out of the switch.
•
Pull cable protector off the old
connecting cord.
Installation is a reversal of the
removal sequence.
- Slip the cable protector, thin end
first, over the new connecting
cord.
•
Check that cable protector is
correctly seated.
- Fit the strain relief clamp
and tighten screws to 1.5 Nm
(1.1 lbf.ft).
•
Fit a new O-ring on gear housing
pivot pin.
- Place a socket (e.g. 19mm)
under the handle housing so that
it supports the bearing bush from
inside.
•
Use press arbor (1) 4116 893
7205 to install needle sleeve in
the bearing bush.
•
Check condition of sealing ring
on oil tank and fit a new one if
necessary - see 9.1.
- Tighten the handle housing
mounting screws to 2.0 Nm
(1.5 lbf.ft).
100RA014
1
VA
100RA011
VA
100RA012
VA
100RA015
VA
100RA010
VA
100RA013
VA
7