FS 260 C, FS 360 C
English
44
Spacer
Check X
Replace
2)
XX
Exhaust port
Decoke after first 139 hours of opera-
tion, then every 150 hours of operation
2)
X
All accessible screws and nuts (not adjust-
ing screws)
Retighten
3)
X
Anti-vibration elements
Visual inspection
4)
XX
Replace
2)
X
Cutting attachment
Visual inspection XX
Replace X
Check tightness XX
Metal cutting attachment Sharpen XX
Safety labels Replace X
1)
Only if there is a noticeable loss of engine power
2)
STIHL recommends that this work be done by a STIHL servicing dealer
3)
Tighten down the muffler mounting screws firmly after first 10 to 20 hours of operation.
4)
see chapter "Inspections and Maintenance by Dealer", section "Antivibration Elements"
The following intervals apply to normal operating conditions only. If your daily work-
ing time is longer or operating conditions are difficult (very dusty work area, etc.),
shorten the specified intervals accordingly.
before starting work
after finishing work or daily
after each refueling stop
weekly
monthly
every 12 months
if problem
if damaged
as required