► Route the perimeter wire (1) toward the front
to the mowing area.
The correct distance to the edge of the mow‐
ing area depends on whether the edge of the
mowing area is navigable, or a distance of
a = 37 cm (length: 1x iMOW
®
Ruler) needs to
be maintained.
► Route the perimeter wire (1) clockwise around
the mowing area,
8.
7.6 Setting up the docking station
in the center of the mowing
area
► Install the perimeter wire (1) in the base plate
so that the guide wire lies flat in the cable duct
and is secured by the hook (2).
► Attach the perimeter wire (1) directly on the
base plate (3) with a fixing pin (4).
► Route the perimeter wire (1) at least 37 cm
(length: 1x iMOW
®
Ruler) away from the base
plate (3) toward the side.
► Route the perimeter wire (1) at least a = 2 m
behind the base plate (3).
► Route the perimeter wire (1) in the center
behind the docking station toward the edge of
the mowing area.
Maintain the correct distance to the edge of
the mowing area depending on the adjacent
area.
► Route the perimeter wire (1) clockwise around
the mowing area,
8.
7 Positioning the docking station English
0458-012-0101-A 21