11 Installing the Perimeter Wire
► Install the perimeter wire(1) with a minimum length of
b=3.3ft. (1m) and with a distance of d=0.4in. (1cm) in
between.
► Fasten the perimeter wire to the ground with two wire
stakes at the edge(A). Do not cross the perimeter wires.
Keep them parallel.
► Attach the search loop to the ground with a sufficient
number of wire stakes.
To install a search loop in combination with an external
docking station:
► Install two search loops(1), each at a 90° angle on the left
and right side of the docking station.
► Keep a minimum clearance of a=6.6ft. (2m) from the
docking station.
To install a search loop in combination with a corridor:
► Install two search loops(1) at an angle of 90° in the part
of the mowing area that can only be reached via a corridor.
► Keep a minimum clearance of a=6.6ft. (2m) from the
corridor entrance.
11.9 Installing Linking Sections
A linking section links a secondary area to the primary
mowing area, e.g. a mowing area in front of and behind the
house that the iMow cannot travel to on its own. This allows
both mowing areas to be mowed automatically.
► Route the perimeter wire(1) parallel and close to one
another.
► Attach the linking section to the ground with a sufficient
number of wire stakes(2).
11.10 Accurate Mowing Along Edges
11
aa
0000-GXX-3404-A0
aa
11
0000-GXX-3405-A0
1
1
2
1