User Manual 5 Electrical Installation
17
5.5 Wiring
5.5.1 Input wiring
Wiring Area Overview
Input wiring hole, as shown in the figure below.
INPUT DC+
Φ11
INPUT DC-
Φ11
Input the rated current of the copper bar 300A. When selecting the
cable specifications, this parameter must be taken into
consideration.
For the cable size less than 0AWG or greater than 50mm
2
, refer to Wiring
scheme 1” for wiring.
For the cable size greater than 0AWG or less than 50mm
2
, refer to Wiring
scheme 2” for wiring.
Wiring scheme 1
Step 1 Use a screwdriver to remove the waterproof terminal assembly from the
bottom of the combiner box (take the version with two waterproof
terminals for example, follow the same the wiring method for the version
with four waterproof terminals).