8
ELECTRICITY
1) Grounding : Make sure that the electricity is properly grounded.
2) Input Voltage (regulate when installing) : 100V, 110V, 120V, 200V, 220V, 240V
3) Available Range of Voltage : On the transformers in the machine are wire taps that can be varied to match
the voltage of the facility. These must be set within 10% of the facility’s voltage.
4) Electric Capacity and Electric Power : Minimum input voltage(640 voltage amps is equivalent to 400
watts.) Each machine should have its own 20amp circuit breaker.
5) Insulation Resistance : The cover of the wires should have a resistance of more than 10 M ohms.
(Measure with 500V insulation tester)
6) Noise (LpAd) should measure 82.6dB (A) working 1200 SPM on SIO 10821-CA M1.
DANGER
Electric shock can result if the machine is not properly grounded. Use a three-
wire grounding (grounding resistance : below 100 ohms)
WARNING
1) Check the voltage supply where the machine is being installed.
2) Install the cable away from the operator’s work space to prevent accident or injury.
3) Have the electrical supply and its installation checked by a certified electrician for
safety’s sake.