6
| Installation
5.1 Location and Space Requirements
The SAVE VSR 300/500 should preferably be installed in a separate room (e.g. storeroom, laundry room or similar.).
When choosing the location it should be kept in mind that
the unit requires maintenance regularly and that the in-
spection door should be easily accessible. Leave free
space for opening the door and for taking out the main
components.
5.2 Outdoor Air Intake Location Recommendation
Recommended installation location for the outdoor air intake is the northern or eastern side of the building and with a
distance to openings for discharge of stale ventilation air, kitchen ventilator, central vacuum system, waste water drain-
age and other pollution sources like exhaust from traffic, etc. Exhaust air should ideally be led via a roof cowl to the out-
side and with a good distance from the outdoor air intake, windows, etc.
5.3 Access to Power supply
The SAVE VSR 300/500 is supplied with approximately 1 1,5 m cable and plug for 230V, single phase earthed
connection.
Make sure a power outlet is reachable by the plug.
6 Installation
Important
The device may only be installed by qualified, instructed and trained personnel. The persons must know
the relevant safety directives in order to recognise and to avoid risks.
333547 | v1.1

Other manuals for SystemAir SAVE VSR 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SystemAir SAVE VSR 300 and is the answer not in the manual?

SystemAir SAVE VSR 300 Specifications

General IconGeneral
BrandSystemAir
ModelSAVE VSR 300
CategoryFan
LanguageEnglish

Related product manuals