17
7.2 Application 2
7.2.1 One zone control
ROOM THERMOSTAT Control for Space heating or cooling need to be set on the user interface. It can be set
in three ways: MODE SET/ONE ZONE/DOUBLE ZONE. The indoor unit can be connected to a high voltage room
thermostat and a low voltage room thermostat. A thermostat transfer board can also be connected. Another six
thermostats can be connected to the thermostat transfer board. Please refer to 8.8.6/6) “For room thermostat” for
wiring. (see 9.5.6 "ROOM THERMOSTAT")
Shut-off valve (Field supply)
Filling valve (Field supply)
Drainage valve (Field supply)
Balance tank (Field supply)
Collector/distributor (Field supply)
Automatic air purge valve
Thermostat transfer board (Optional)
Low voltage room thermostat (Field supply)
P_o: Outside circulation pump (Field
supply)
High voltage room thermostat (Field supply )
Expansion vessel (Field supply)
1…n
Floor heating loop (Field supply)
Space heating
One zone control: the unit ON/OFF is controlled by the room thermostat, cooling or heating mode and outlet
water temperature are set on the user interface. System is ON when any “HL” of all the thermostats closes. When
all “HL” open, system turns OFF.
The circulation pumps operation
When the system is ON, which means any “HL” of all the thermostats closes, P_o(6) starts running; When the
system is OFF, which means all “HL” close, P_o (6) stops running.