4. Installation Fundamentals
Leakage /Freon - 1/4
Case-1
90˚
Key Factor
Pipe cutting
Gas leaks due to the mal-flared copper pipes with non-rectangular section.
Troubles &
Causes
Defect Details
Guidelines
Pipe cutter
Pipe cutter
Make pipe straight before
cutting, and it makes a
rectangular section.
Cu. pipe
Cu. pipe
Cutting curved pipe leads
mal-rectangular section.
And it makes gas leakage.
20