EasyManuals Logo
Home>Technics>Cassette Player>RS-B465

Technics RS-B465 Service Manual

Technics RS-B465
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
RS-B465
OVERALL
FREQUENCY
RESPONSE
1.Insert
the
a
Normal
blank
test
tape
(QZZCRA)
and
set
the
unit
to
the
Record
Pause
mode.
2.Apply
a
reference
input
signal
(1
kHz,
-24
dB)
through
an
attenuator.
3.Attenuate
the
signal
by
20
dB
and
adjust
the
frequency
from
50
Hz
~
10.0kHz.
4.Record
the
frequency
sweep.
5.Playback
the
recorded
signal
and
assure
that
it
is
within
the
range
shown
in
Fig.8
in
comparison
to
the
reference
frequency
(1
kHz).
6.If
it
is
not
within
the
standard
range,
adjust
VR301
(L-CH)
and
VR302
(R-CH)
so
that
the
frequency
level
is
within
the
standard
range.
7.Repeat
steps
2
~
6
above
using
the
CrOz
tape(QZZCRX)
and
the
Metal
tape(QZZCRZ)
increasing
the
frequency
range
to
12.5kHz
(60Hz2~12.5kHz).
8.Assure
that
the
level
is
within
the
range
shown
in
Fig.9.
LINE
IN
LINE
OUT
AF
oscillator
ATT
EVM
Oscilloscope
¢
Adjustment
points
MAIN
PC.B.
TAPE
SPEED
ADJ.
VR9OI
(XI)
VR302
VR30l
Normal
Overall
frequency
response
chart
(NR
OUT)
5OHz
100Hz
200Hz
SOOHZ
1kHz
2kHz
Fig.8
CrO,-Metal
Overall
frequency
response
chart
(NR
OUT)
5OKz
100Hz
200Hz
SO0H2
1kHz
2kHz
12.5kHz2
Fig.9
Line
Line
Out
in
LJ]
=
PLAYBACK
GAIN
ADJ.
VRi
(Leh,
VR2(Rch)
=
OVERALL
GAIN
ADJ.
VR3(Lch),
VR4(Rch)
OVERALL
FREQUENCY
RESPONSE
ADJ.
VR3Ol(Lch),
VR302(Rch)