EasyManuals Logo
Home>Technics>Turntable>SL-221 (X)

Technics SL-221 (X) User Manual

Technics SL-221 (X)
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
=
TROUBLE
SHOOTING
GUIDE
*
Except
when
check
ing
voltage,
disconnect
the
power
cord
before
repair
without
fail.
A.
Switching
on
does
not
cause
1.
Come
off
belt
from
capstan
TROUBLE
Turntable
speed
Instali
the
belt
to
capstan.
turntable
to
rotate.
(Remove
bottom
cover
and,
using
DC
voltmeter,
check
printed
base
voltage)
No
output
of
constant-voitage
circuit
(1)
No
output
on
secondary
of
transformer.
*
Cord
disconnected.
*
Replace
cord.
Soldered
improperly.
Solder
securely.
Power
transformer
defective.
Replace
power
transformer.
Output
of
cnstant-voltage
circuit
is
96~14.4V.
Motor
ass’y
defective.
Replace
motor
ass‘y:
Speed
selector
switch
defective
*
Contact
faulty.
*
Replace
speed
selector
switch.
Soldered
improperly.
Solder
securely.
B.
Turntable
speed
too
slow.
Constant-voltage
output
is
not
9.6V
~
14.4V.
Power
transformer
defective.
Replace
power
trans.
2.
Constant
voitage
output
is
9.6V
~
14.4V.
*
Motor
ass‘y
defective.
*
Replace
motor
ass’y.
Adjust
semi-fixed
resistor
VR3
&
VR4.
Speed
unadjusted.
C.
Turntable
speed
too
fast.
1.
Constant-voltage
output
is
not
9.6
~
14.4V,
Power
transformer
defective.
Replace
power
transformer.
2.
Constant-voltage
output
is
9.6V
~
14.4V.
Motor
ass’y
defective.
Replace
motor
ass‘y.
Speed
unadjusted.
Adjust
semi-fixed
resistor
VR3
&
VR4.
roe
fj
D.
Turntable
speed
varies
too
much.
*
Motor
ass‘y
defective.
*
Replace
motor
ass‘y.
*
Replace
belt.
*
Belt
defective.
ceeerees
Turntable.
after
stopped
by
hand.
*
Motor
ass’y
defective.
*
Replace
motor
ass’y.
will
not
tusn
or
starts
turning
but
will
stop
soon.
Operative
at
only
one
of
two
*
Speed
selector
switch
defective.
*
Replace
speed
selector
switch.
speeds.
*
Leadwire
disconnected
or
unsoldered.
*
Replace
leadwire,
or
solder
securely.
(33-1/3
r.p.m
or
45
r.p.m)
*
Contact
of
VR1,
VR2
insufficient.
*
Replace
printed
base
ass’y.
G.
When
actuating,
turntable
speed
zi
*
Motor
ass‘y
defective.
*
Replace
motor
ass‘y.
is
unsteadly
for
along
time.
Noise
Power
transformer
makes
loud
noise
Replace
power
transformer.
Offensive
noise
is
hears.
of
vibration.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technics SL-221 (X) and is the answer not in the manual?

Technics SL-221 (X) Specifications

General IconGeneral
BrandTechnics
ModelSL-221 (X)
CategoryTurntable
LanguageEnglish

Related product manuals