EasyManuals Logo
Home>Technics>Turntable>SL-Q2

Technics SL-Q2 User Manual

Technics SL-Q2
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
We
want
to
thank
you
for
selecting
the
SL-Q2.
For
optimum
performance,
we
recommend
that
you
read
these
instructions
carefully.
Caution
for
safe
use
of
this
apparatus
Caution
e
This
apparatus
is
double
insulated,
safety
earth
not
re-
quired.
Important
e
The
wires
in
this
mains
lead
are
coloured
in
accordance
with
the
following
code:
Blue:
Neutral
Brown:
Live
As
the
colours
of
the
wires
in
the
mains
lead
of
this
ap-
paratus
may
not
correspond
with
the
coloured
markings
identifying
the
terminals
in
your
plug
proceed
as
follows.
The
wire
which
is
coloured
BLUE
must
be
connected
to
the
terminal
which
is
marked
with
the
letter
N
or
coloured
BLACK.
The
wire
which
is
coloured
BROWN
must
be
connected
to
the
terminal
which
is
marked
with
the
letter
L
or
coloured
RED.
¢
This
equipment
should
be
disconnected
from
the
mains
when
not
in
use.
Before
use
Caution:
Never
connect
the
AC
power
plug
before
assembly
has
been
completed.
Attach
the
dust
cover
last,
so
that
assembly
and
adjustments
can
be
made
most
conveniently.
@
Checklist
of
parts
Turntable
unit
Turntable
platter...
.
cece
cece
cece
e
eee
tener
een
es
1
Turntable
mat
Dust
cover
Piste
45-rpM
AdAPLOL
oo
secre
cece
eee
nese
eee
nee
e
eee
e
een
ee
1
Balance
weight
41
Headshell/cartridge
6.6...
0.
cece
cece
e
eee
e
rete
renees
1
Shell
weight
0.0.0...
ce
es
cette
eee
eee
e
eet
eee
eee
1
Assembly
and
set-up
@
Installation
of
turntable
platter
1.
Place
the
turntable
platter
on
the
center
spindle.
Note:
The
rotor
is
connected
to
the
underside
of
the
turntable
platter.
(The
magnet
of
the
motor
is
attached
to
the
turn-
table
platter.)
To
maintain
optimum
performance,
extra
care
should
be
taken
to
prevent
adhesion
of
dust
or
iron
filings
to
the
magnet
and
not
to
damage
the
magnet
by
dropping
it.
Do
not
remove
or
loosen
the
screws.
Should
the
position
of
the
fixed
magnet
be
altered
by
loosening
the
securing
screws,
the
rated
performance
of
the
unit
cannot
be
guar-
anteed.
(See
Fig.
2.)
2.
Place
the
turntable
mat
on
the
platter.
Note:
After
having
placed
the
turntable
mat
on
the
turntable
platter,
manually
rotate
the
turntable
platter
clockwise
about
10
times.
This
will
disengage
the
automatic
mechanism
from
the
tonearm
gear,
which,
in
rare
cases,
may
have
moved
out
of
its
normal
position
during
transportation.
B
Installation
of
headshell
(See
Fig.
3.)
Insert
the
headshell
into
the
front
end
of
the
tubular
arm,
and
turn
the
locking
nut
clockwise
(in
the
direction
shown
by
the
arrow
“A”),
with
the
headshell
firmly
held
horizontally.
i
Installation
of
balance
weight
(See
Fig.
4.)
Place
the
balance
weight
on
the
rear
shaft
of
the
tonearm.
H
Adjustments
of
horizontal
zero
(0)
balance
and
stylus
pressure
1.
Remove
the
stylus
protector,
if
your
cartridge
has
a
detach-
able
one.
Be
careful
not
to
touch
your
fingers
to
the
stylus
tip.
2.
Release
the
arm
clamp
and
lift
the
tonearm
from
the
arm
rest
to
free
it.
3.
Turn
the
entire
balance
weight
clockwise
(indicated
by
the
arrow
“A”)
or
counterclockwise
(indicated
by
the
arrow
“B”)
until
the
tonearm
is
approximately
balanced
horizon-
tally
(floats
freely).
(See
Figs.
5
and
6.)
Note:
Fig.
6-1
Excessive
forward
advancement
of
the
balance
weight
causes
the
cartridge
side
to
be
lowered.
Fig.
6-2
Excessive
backward
retreatment
of
the
balance
weight
causes
the
cartridge
side
to
be
raised.
Fig.
6-3
Upon
balancing
between
the
balance
weight
and
car-
tridge,
the
tonearm
is
held
horizontal.
|
During
the
adjustment
of
the
horizontal
zero
(0)
balance,
be
careful
that
the
stylus
tip
of
the
cartridge
does
not
contact
the
turntable
mat
or
turntable
base.
4.
After
the
tonearm
is
horizontally
zero
(0)
balanced,
tem-
porarily
refasten
the
tonearm
with
the
arm
clamp.
5.
Hold
the
balance
weight
stationary
with
one
hand
as
shown
in
the
picture,
and
rotate
only
the
stylus-pressure
ring
to
bring
the
numeral
“0”
of
the
ring
into
alignment
with
the
center
line
on
the
tonearm
rear
shaft.
The
adjustment
of
the
horizontal
zero
(0)
balance
is
now
completed,
(See
Fig.
7.)
6.
After
adjusting
the
horizontal
zero
(0)
balance,
turn
the
balance
weight
clockwise
in
the
direction
of
the
arrow
and
align
to
the
correct
stylus
pressure.
(See
Fig.
8.)
(The
stylus
pressure
of
this
unit
is
1.75
g.)
Note:
Set
the
stylus
pressure
to
the
maximum
recommended
value
for
your
cartridge
in
cases
where
the
record
has
an
extremely
high
recording
level,
or
where
the
unit
is
operat-
ed
in
a
room
at
low
temperature,
or
in
places
in
which
the
unit
is
subjected
to
vibrations.
®
Adjustment
of
anti-skating
contro!
Set
the
anti-skating
control
knob
to
the
same
value
as
the
stylus
pressure.
(See
Fig.
9.)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Technics SL-Q2 and is the answer not in the manual?

Technics SL-Q2 Specifications

General IconGeneral
BrandTechnics
ModelSL-Q2
CategoryTurntable
LanguageEnglish

Related product manuals